  § 113.87   Operations in the thermal processing room.

  (b) A system for product traffic control in the retort room shall be established to prevent unretorted product from bypassing the retort process. Each retort basket, truck, car, or crate used to hold containers in a retort, or one or more containers therein, shall, if it contains any retorted food product, be plainly and conspicuously marked with a heat-sensitive indicator, or by other effective means that will indicate visually, to thermal processing personnel, those units that have been retorted. A visual check shall be performed to determine whether or not the appropriate change has occurred in the heat-sensitive indicator as a result of retorting for all retort baskets, trucks, cars, or crates, to ensure that each unit of product has been retorted. A record of these checks should be made.

  (c) The initial temperature of the contents of the containers to be processed shall be accurately determined and recorded with sufficient frequency to ensure that the temperature of the product is no lower than the minimum initial temperature specified in the scheduled process. For those operations that use water during the filling of the retort or during processing, provision shall be made to ensure that the water will not, before the start of each thermal process, lower the initial temperature of the product below that specified in the scheduled process. The temperature-indicating device used to determine the initial temperature shall be tested for accuracy against a reference device for which the accuracy is traceable to a National Institute of Standards and Technology (NIST), or other national metrology institute, standard reference device, by appropriate standard procedures, with sufficient frequency to ensure that initial temperature measurements are accurate. Records of the accuracy of the temperature-indicating device and of a reference device that is maintained by the processor shall be established and maintained in accordance with §113.100(c) and (d).

  (e) Clock times on temperature-recording device records shall reasonably correspond to the time of day on the processing records to provide correlation of these records.

  更多关于美国FDA酸化食品HACCP法规,请详见美国FDA酸化食品HACCP法规第113和114部分汇总

 地区: 美国 
 标签: 杀菌 计量 追溯 标准 
食品伙伴网提供标准法规解读、舆情监控、合规咨询、申报注册等服务。
电询:0535-2129301
QQ:2891238009
食品标法圈
实时把握食品标法动态
请扫码关注食品标法圈

声明:

① 凡本网所有原始/编译文章及图片、图表的版权均属食品伙伴网所有,如要转载,需注明“信息来源:食品伙伴网”。
② 凡本网注明“信息来源:XXX(非食品伙伴网)”的作品,均转载自其他媒体,转载目的在于传递更多的信息,并不代表本网赞同其观点和对其真实性负责。
※ 邮箱:law#foodmate.net(发邮件时请将#换成@) QQ:139307733

 
 
[ 政策法规搜索 ]  [ 加入收藏 ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]

 

 
 
按分类浏览
国家法规 (11844) 国外法规 (3603)
地方法规 (41828) 法规动态 (12)
法规解读 (2903) 其他法规 (536)
推荐国外法规
点击排行
    按国家或地区浏览

    法规中心  关于我们  广告业务  联系我们  信息服务

    Processed in 0.031 second(s), 10 queries, Memory 4.45 M